Firmware documentation for the STM32 Sinker EDM controller: Keil uVision project structure, state machines, pulse-monitoring and gap-control logic, and safety/fault handling.
Target: STM32F103C8 (“Blue Pill”) · Toolchain: Keil uVision (MDK-ARM) · Code generation: STM32CubeMX · Peripheral drivers: STM32 LL (Low-Layer) · Core clock: 72 MHz (8 MHz HSE + PLL ×9)
The firmware follows a cooperative super-loop + interrupt-driven drivers architecture:
main() and orchestrates the whole machine: capacitor charging, arming, gap approach, machining and safe shutdown. It never blocks; all waits are timestamp comparisons against a 1 ms SysTick counter (sys_tick_ms).IsBusy() flags:
btn_go_pressed, btn_a_pressed, btn_b_pressed); the FSM consumes and clears them.flowchart LR
BTN[Buttons GO / A / B<br/>EXTI] -->|btn_*_pressed flags| FSM
TICK[SysTick 1 ms<br/>sys_tick_ms] --> FSM
FSM[Main FSM<br/>main.c] -->|RunCycle Once / Train| DIS[Discharge driver<br/>TIM1 + CC IRQ]
FSM -->|Slow / Mid / Fast| STP[Stepper driver<br/>TIM2 update IRQ]
DIS -->|IsBusy| FSM
STP -->|IsBusy| FSM
DIS -->|sparks / shorts| FSM
FSM -->|GPIO| PWR[Relays, bleeder MOSFET, LEDs]
DIS -->|PWM CH1 / CH1N / CH2| GATE[Gate drivers]
STP -->|STEP / DIR| MOTOR[Stepper driver board]
The project was generated with STM32CubeMX and then reorganized so that everything lives under the MDK-ARM folder, next to the .uvprojx project file. The CubeMX project (.ioc) sits in the same place, so the hardware configuration and the firmware can be opened and regenerated from one location. Include paths in the Keil project options point to these folders, and the project builds with all modules resolving each other.
MDK-ARM/
├── <project>.uvprojx # Keil uVision project
├── <project>.ioc # STM32CubeMX configuration (pins, clocks, peripherals)
├── Core/
│ ├── Inc/ # main.h, discharge.h, stepper.h, global_vars.h, tim.h, adc.h, ...
│ └── Src/ # main.c, discharge.c, stepper.c, tim.c, adc.c, ...
├── Drivers/
│ ├── CMSIS/ # Core and device headers
│ └── STM32F1xx_HAL_Driver/ # LL driver headers and sources
└── Files/ # Additional project files
| Module | Files | Responsibility |
|---|---|---|
| Main FSM | main.c, main.h |
System init, clock tree, pin map, state machine, safe-state handling, error handler |
| Discharge driver | discharge.c, discharge.h |
TIM1-based pulse generation (single pulse or pulse train), busy flag, CC interrupt handler |
| Stepper driver | stepper.c, stepper.h |
TIM2-based STEP/DIR generation, three move profiles, busy flag |
| Shared variables | global_vars.h |
Flags and counters shared between ISRs and the FSM (sys_tick_ms, btn_*_pressed, sparks, shorts, I_Limit_Max, completed_steps) |
| Peripheral init | tim.c, adc.c, dma.c, gpio.c, usart.c |
CubeMX-generated initialization (TIM1, TIM2, TIM4, ADC1 + DMA, USART2, GPIO) |
USER CODE BEGIN / END blocks, so the .ioc can be modified and the code regenerated without losing user code.USER CODE BEGIN PD / PTD in main.h.static helpers (LED, relay and MOSFET wrappers) are kept private to main.c; headers only expose the public API.Init(), one or more Run...() start functions, IsBusy() and an IRQHandler() called from the corresponding interrupt vector.| Function | Pin | Notes |
|---|---|---|
| LED green | PB4 | Driven LOW = ON |
| LED red | PB3 | Driven LOW = ON |
| LED safe | PC13 | Driven LOW = ON (bleeding indicator) |
| Master relay | PB5 | Driven HIGH = ON |
| Charge relay | PB7 | Driven LOW = ON |
| Bleeder MOSFET | PB1 | Driven LOW = ON |
| Button GO | PA4 | External pull-up, active LOW, EXTI4 falling edge |
| Button A | PA15 | External pull-up, active LOW |
| Button B | PA10 | External pull-up, active LOW |
| TIM1_CH1 | PA8 | Discharge PWM |
| TIM1_CH1N | PB13 | Complementary discharge PWM |
| TIM1_CH2 | PA9 | Discharge PWM (second channel) |
| TIM1_BKIN | PB12 | Hardware break input (active LOW) |
| Stepper STEP | PA2 | Z-axis step pulse |
| Stepper DIR | PB10 | Z-axis direction (BAJA = LOW, SUBE = HIGH) |
PB3, PB4 and PA15 are freed from JTAG at start-up with LL_GPIO_AF_Remap_SWJ_NOJTAG() (SWD stays available for debugging).
| Timer | Role | Resolution |
|---|---|---|
| SysTick | 1 ms system time base (sys_tick_ms) |
1 ms |
| TIM1 | Discharge pulses (PWM + compare events) | 1 µs per tick (prescaler 71) |
| TIM2 | Stepper step-rate timebase | 0.5 µs per tick (prescaler 35, with a 72 MHz timer clock) |
The NVIC uses priority grouping 4 (4 bits of pre-emption, no sub-priority). A lower number means higher priority.
| Interrupt | Priority | Purpose |
|---|---|---|
TIM1_CC_IRQn |
0 (highest) | Discharge pulse events (CC3, CC4): pulse timing is the most critical task |
TIM2_IRQn |
5 | Stepper step generation |
SysTick_IRQn |
15 (lowest) | 1 ms time base for the FSM |
The main FSM lives in main.c and is implemented as a switch (app_state) inside the super-loop. Every state is non-blocking.
stateDiagram-v2
direction TB
[*] --> STATE_IDLE : power-up / all_outputs_safe()
STATE_IDLE : IDLE
STATE_IDLE : green LED blinks 500 ms
STATE_IDLE : relays OFF
STATE_RELAY_ON : RELAY_ON
STATE_RELAY_ON : master and charge relays ON
STATE_RELAY_ON : red LED steady, bleeder OFF
STATE_WAIT_XMS : WAIT_XMS
STATE_WAIT_XMS : charge relay released
STATE_WAIT_XMS : buttons ignored
STATE_READY : READY
STATE_READY : green LED steady
STATE_READY : sparks = 0, shorts = 0
STATE_READING : READING
STATE_READING : evaluate sparks and shorts
STATE_READING : decide step or discharge
STATE_FORWARD : FORWARD
STATE_FORWARD : stepper moving down
STATE_BACKWARD : BACKWARD
STATE_BACKWARD : stepper moving up
STATE_DISCHARGE_CONT : DISCHARGE_CONT
STATE_DISCHARGE_CONT : single or train discharge running
STATE_DISCHARGE_ONCE : DISCHARGE_ONCE
STATE_DISCHARGE_ONCE : debug path only
STATE_BLEEDING : BLEEDING
STATE_BLEEDING : relays OFF, bleeder ON
STATE_BLEEDING : safe LED blinks 200 ms
STATE_LOCKOUT : LOCKOUT
STATE_LOCKOUT : red LED blinks 200 ms
STATE_LOCKOUT : I_Limit_Max = 0, buttons ignored
%% Power-up sequence
STATE_IDLE --> STATE_RELAY_ON : btn_go_pressed
STATE_RELAY_ON --> STATE_WAIT_XMS : 8000 ms elapsed
STATE_WAIT_XMS --> STATE_READY : 100 ms elapsed
%% Ready branches
STATE_READY --> STATE_READING : btn_go_pressed
STATE_READY --> STATE_LOCKOUT : btn_a_pressed / Stepper_Mov_Rapido(SUBE)
STATE_READY --> STATE_BLEEDING : btn_b_pressed / master relay OFF
%% Machining loop
STATE_READING --> STATE_READY : down_steps_done above 3500
STATE_READING --> STATE_DISCHARGE_CONT : sparks above 1 and sparks above shorts / Discharge_RunCycle_Train()
STATE_READING --> STATE_FORWARD : no sparks and no shorts / Stepper_Aprox_Inicial(BAJA)
STATE_READING --> STATE_BACKWARD : otherwise / Stepper_Mov_Mid(SUBE)
STATE_FORWARD --> STATE_DISCHARGE_CONT : stepper idle / Discharge_RunCycle_Once()
STATE_BACKWARD --> STATE_DISCHARGE_CONT : stepper idle / Discharge_RunCycle_Once()
STATE_DISCHARGE_CONT --> STATE_READING : discharge idle
STATE_DISCHARGE_CONT --> STATE_LOCKOUT : discharge idle and btn_b_pressed
STATE_DISCHARGE_ONCE --> STATE_READING : discharge idle
%% Exit paths
STATE_LOCKOUT --> STATE_READY : 500 ms elapsed
STATE_BLEEDING --> STATE_IDLE : 8000 ms elapsed
%% Fallback
note right of STATE_IDLE
default case in switch:
all_outputs_safe() then IDLE
end note
DISCHARGE_ONCEalso exists in the state enum (single pulse, then back toREADING). It is only reachable through a commented-out debug path and is not part of the normal flow.
| State | Indicators | Behavior | Exit condition |
|---|---|---|---|
| IDLE | Green LED blinks (500 ms) | Relays off, waiting for the operator | btn_go_pressed → RELAY_ON |
| RELAY_ON | Red LED steady | Master and charge relays ON, bleeder OFF; capacitors charge | 8 s elapsed (TIME_RELAY_WAIT_MS) |
| WAIT_XMS | Red LED steady | Charge relay released; buttons ignored | 100 ms elapsed (TIME_RELAY_DEL_WAIT_MS) |
| READY | Green LED steady | Machine armed; sparks and shorts cleared every pass |
GO → READING, A → LOCKOUT, B → BLEEDING |
| READING | Both LEDs on | Decision state: waits for the discharge driver to be idle, then evaluates sparks / shorts (see section 7) |
One of four outcomes |
| FORWARD | – | Waits for the stepper to finish a downward move, then fires a single discharge | Stepper idle → DISCHARGE_CONT |
| BACKWARD | – | Waits for the stepper to finish an upward move, then fires a single discharge | Stepper idle → DISCHARGE_CONT |
| DISCHARGE_CONT | LEDs off | Pulse train or single discharge running | Driver idle: B pressed → LOCKOUT, else → READING |
| BLEEDING | Safe LED blinks (200 ms) | Master relay off; after 100 ms the bleeder MOSFET turns on; buttons ignored | 8 s elapsed (TIME_BLEEDING_WAIT_MS) → IDLE |
| LOCKOUT | Red LED blinks (200 ms) | Short forced pause; I_Limit_Max cleared; buttons ignored |
500 ms elapsed (TIME_LOCKOUT_MS) → READY |
| default | – | Unknown state: all_outputs_safe() and restart from IDLE |
Immediate |
| Button | In READY |
In DISCHARGE_CONT |
Other states |
|---|---|---|---|
| GO | Start automatic machining | – | IDLE: start charging. Ignored elsewhere |
| A | Fast move up, then lockout | – | Ignored |
| B | Controlled power-down (bleeding) | Stop machining → LOCKOUT |
Ignored |
Button flags are explicitly cleared in states where input must not be latched (WAIT_XMS, BLEEDING, LOCKOUT), so a press made during a non-interactive phase can never trigger an action later.
Files: discharge.c, discharge.h
The driver turns TIM1 into a small, self-stopping pulse generator. The FSM calls a RunCycle function and then polls Discharge_IsBusy(); everything in between happens in the TIM1_CC interrupt.
One pulse is defined by four compare values, with 1 tick = 1 µs:
| Parameter | Define | Value | Meaning |
|---|---|---|---|
| ARR | T_TOTAL_US |
60 | Total pulse length (about 60 µs) |
| CCR1 | T_CH1_TO_LOW_US |
23 | CH1 is HIGH until this tick (PWM1 mode); CH1N is its complement with dead-time |
| CCR2 | T_CH2_TO_HIGH_US |
11 | CH2 goes HIGH at this tick (active-on-match mode) |
| CCR4 | T_CH2_TO_LOW_US |
50 | ISR forces CH2 LOW at this tick |
| CCR3 | T_TOTAL_US - 1 |
59 | End-of-pulse event, one tick before the update event |
tick 0 11 23 50 59 60
CH1 ############################|_____________________________
CH1N (complement of CH1, separated by dead-time)
CH2 ___________|###########################|__________________
CC3 ^ end-of-pulse event
| Function | Type | Behavior |
|---|---|---|
Discharge_RunCycle_Once() |
Single pulse | One pulse, then the timer stops and the driver goes idle |
Discharge_RunCycle_Train() |
Pulse train | NUM_PULSES (8) back-to-back pulses, then stop |
stateDiagram-v2
direction LR
[*] --> DIS_IDLE : Discharge_Init() / tim1_stop()
DIS_IDLE : IDLE
DIS_IDLE : dis_busy = 0
DIS_IDLE : timer stopped, MOE = 0
DIS_IDLE : CH2 mode = ACTIVE
DIS_ONCE : RUNNING SINGLE
DIS_ONCE : dis_busy = 1
DIS_ONCE : tipo_descarga = 0
DIS_TRAIN : RUNNING TRAIN
DIS_TRAIN : dis_busy = 1
DIS_TRAIN : tipo_descarga = 1
DIS_TRAIN : cont_pulsos counts pulses
DIS_IDLE --> DIS_ONCE : Discharge_RunCycle_Once() / tim1_fire()
DIS_IDLE --> DIS_TRAIN : Discharge_RunCycle_Train() / cont_pulsos = 0, tim1_fire()
DIS_ONCE --> DIS_IDLE : CC3 event / tim1_stop(), dis_busy = 0
DIS_TRAIN --> DIS_TRAIN : CC3 event, cont_pulsos below NUM_PULSES / re-arm CH2 (OCMODE_ACTIVE)
DIS_TRAIN --> DIS_IDLE : CC3 event, cont_pulsos reached NUM_PULSES / tim1_stop(), dis_busy = 0
note right of DIS_TRAIN
Inside every pulse (1 tick = 1 us)
0 : CH1 HIGH, CH1N complementary
CCR2 (11) : CH2 HIGH
CCR1 (23) : CH1 LOW
CC4 (50) : ISR forces CH2 LOW (FORCED_INACTIVE)
CC3 (59) : end of pulse event
ARR (60) : counter wraps
end note
FORCED_INACTIVE. This is needed because in “active on match” mode the output goes HIGH on a compare match but never returns LOW by itself.tim1_stop() and dis_busy = 0.OCMODE_ACTIVE (re-arm) and the counter wraps to start the next pulse. Without this step, CH2 would stay in forced-inactive mode and never fire again.tim1_stop() always leaves the timer safe: counter disabled, compare interrupts and flags cleared, CH2 re-armed, and MOE = 0 so the outputs return to their configured idle levels.Discharge_Init() loads all compare registers with 65535 (greater than ARR) so no output can go active before the first cycle is requested.Files: stepper.c, stepper.h
The Z axis (electrode feed) is driven by STEP/DIR pulses generated entirely from the TIM2 update interrupt. The FSM only requests a move and polls Stepper_IsBusy().
| Function | Steps | Approx. duration | Used for |
|---|---|---|---|
Stepper_Mov_Slow(dir) |
NUM_APROX_STEPS = 1 |
≈ 0.3 ms | Fine approach towards the workpiece |
Stepper_Mov_Mid(dir) |
NUM_STEPS_MID = 50 |
≈ 15 ms | Retract after short circuits |
Stepper_Mov_Rapido(dir) |
NUM_QUICK_STEPS = 35000 |
≈ 10.5 s | Fast travel (button A) |
Direction constants: BAJA (0) moves down, SUBE (1) moves up. TIME_BETWEEN_STEPS (300 ticks) sets the time per STEP phase: about 150 µs per phase, 300 µs per full step (≈ 3.3 kHz).
One full step takes two interrupts: a rising edge (counted as a step) and a falling edge.
stateDiagram-v2
direction LR
[*] --> STEP_IDLE : Stepper_Init() / Stepper_Stop()
STEP_IDLE : IDLE
STEP_IDLE : step_busy = 0
STEP_IDLE : TIM2 stopped, STEP low
STEP_IDLE : completed_steps = 0
STEP_LOW : STEP LOW phase
STEP_LOW : step_busy = 1
STEP_LOW : step_state = 0
STEP_HIGH : STEP HIGH phase
STEP_HIGH : step_busy = 1
STEP_HIGH : step_state = 1
STEP_IDLE --> STEP_LOW : Stepper_Mov_Slow / Mov_Mid / Mov_Fast - set planned_steps and DIR, start TIM2
STEP_LOW --> STEP_HIGH : TIM2 update, completed_steps below planned_steps / step_high(), completed_steps++
STEP_HIGH --> STEP_LOW : TIM2 update, completed_steps below planned_steps / step_low()
STEP_HIGH --> STEP_IDLE : TIM2 update, completed_steps reached planned_steps / step_low(), Stepper_Stop()
STEP_LOW --> STEP_IDLE : Stepper_Stop() called externally
STEP_HIGH --> STEP_IDLE : Stepper_Stop() called externally
note right of STEP_IDLE
Move sizes (planned_steps)
Mov_Slow : NUM_APROX_STEPS = 1
Mov_Mid : NUM_STEPS_MID = 50
Mov_Rapido : NUM_QUICK_STEPS = 35000
Phase time = TIME_BETWEEN_STEPS ticks
1 step = 2 TIM2 interrupts
Calls while busy return 0 and are ignored
end note
Stepper_Stop() can be called at any time: it disables TIM2, forces STEP low and clears the internal counters. The same function is used automatically when a move completes.The quality of the spark gap is evaluated per discharge cycle using two counters shared with the FSM:
| Variable | Meaning |
|---|---|
sparks |
Number of effective sparks counted in the last cycle |
shorts |
Number of short-circuit events counted in the last cycle |
I_Limit_Max |
Over-current limit counter, cleared in LOCKOUT |
The counters are reset to zero in READY and after every decision, so each evaluation only reflects the cycle that just finished.
STATE_READING)Once the discharge driver is idle, the FSM evaluates the counters in this priority order:
| # | Condition | Action | Next state |
|---|---|---|---|
| 1 | down_steps_done > 3500 |
Gap not found after too many approach steps: abort and clear counters | READY |
| 2 | sparks > 1 and sparks > shorts |
Good machining condition: run a pulse train (NUM_PULSES) |
DISCHARGE_CONT |
| 3 | sparks < 1 and shorts < 1 |
Gap too open: advance 1 step down (BAJA), down_steps_done++ |
FORWARD |
| 4 | Otherwise (shorts dominate) | Gap too small: retract 50 steps (SUBE), down_steps_done = 0 |
BACKWARD |
After a move (FORWARD / BACKWARD) the FSM fires a single probe pulse and re-evaluates. This produces a closed-loop behavior:
flowchart TD
A[READING: discharge idle] --> B{down_steps_done above 3500?}
B -- yes --> R[Abort, back to READY]
B -- no --> C{sparks above 1<br/>and sparks above shorts?}
C -- yes --> T[Pulse train<br/>keep machining]
C -- no --> D{no sparks<br/>and no shorts?}
D -- yes --> F[Step down 1 step<br/>then probe pulse]
D -- no --> K[Retract 50 steps<br/>then probe pulse]
T --> A
F --> A
K --> A
In practice the electrode creeps towards the workpiece one step at a time while the gap is open, backs off when short circuits dominate, and stays put (pulsing) while the spark count is healthy (how is evaluated is addressed ahead).
The machine stores energy in capacitors, so the firmware is organized around one rule: every path ends in a known safe state.
| Hazard | Mitigation |
|---|---|
| Undefined outputs at start-up | all_outputs_safe() runs before any driver is initialized: LEDs off, master relay off, bleeder MOSFET on |
| Unsafe timer outputs | Discharge_Init() loads compare values above ARR so no channel can go active; tim1_stop() clears MOE so the outputs return to their configured idle levels |
| Shoot-through on complementary outputs | CH1 / CH1N are complementary with hardware dead-time (DeadTime = 76, about 1.06 µs) |
| External fault on the power stage | TIM1 break input (PB12, active LOW) is enabled with OSSI / OSSR; automatic output re-enable is disabled, so outputs only restart through software |
| Overlapping cycles | Discharge and stepper drivers ignore new requests while busy |
| Premature operation after power-up | Capacitors charge for 8 s, then the charge relay is released and a 100 ms settling time is enforced before READY; buttons are ignored during this phase |
| Stored energy after shutdown | BLEEDING state: master relay off, 100 ms later the bleeder MOSFET turns on, safe LED blinks for 8 s, and the machine returns to IDLE only afterwards |
| Operator stop during machining | Button B during DISCHARGE_CONT ends the sequence once the current (sub-millisecond) cycle completes and enters LOCKOUT |
| Endless gap search | Automatic abort to READY after 3500 (NUMBER_STEPS_DOWN_MAX) consecutive approach steps without finding the gap |
| Accidental or latched inputs | Button flags are cleared in every state that must not react to them |
| Over-current events | I_Limit_Max counter is cleared in LOCKOUT before machining resumes |
| Corrupted or unknown FSM state | default branch calls all_outputs_safe() and restarts from IDLE |
| Unrecoverable error | Error_Handler() disables all interrupts, forces safe outputs and halts in an infinite loop |
The source keeps a few commented-out blocks marked DEBUG. They are not needed for normal operation; they were used during bring-up and bench testing and can be removed or re-enabled:
| Item | Purpose |
|---|---|
tren, sparks_effective, sparks_ineffective, test_start_ms, test_elapsed_ms |
Counters for spark-efficiency tests |
TARGET_SPARKS (10000) |
Stop condition for timed spark-count tests |
STATE_DISCHARGE_ONCE |
Single-pulse state for isolated pulse testing |
Discharge_RunCycle_Train() in STATE_READY |
Approach test without electrolysis |
Alternate STEP/DIR pins (PB0 / PA7) in stepper.c |
Test of a second driver on another axis |
| Constant | File | Value | Description |
|---|---|---|---|
TIME_RELAY_WAIT_MS |
main.h |
8000 | Capacitor charge time |
TIME_RELAY_DEL_WAIT_MS |
main.h |
100 | Settling time after relay release / before bleeder |
TIME_LOCKOUT_MS |
main.h |
500 | Lockout duration |
TIME_BLEEDING_WAIT_MS |
main.h |
8000 | Total bleeding time |
TIME_BLINK_IDLE_MS |
main.h |
500 | Green LED blink period in IDLE |
TIME_BLINK_LOCKOUT_MS |
main.h |
200 | Red / safe LED blink period |
NUMBER_STEPS_DOWN_MAX |
main.h |
35000 | steps |
T_TOTAL_US |
discharge.h |
60 | Pulse length (µs) |
T_CH1_TO_LOW_US |
discharge.h |
23 | CH1 HIGH time (µs) |
T_CH2_TO_HIGH_US |
discharge.h |
11 | CH2 start (µs) |
T_CH2_TO_LOW_US |
discharge.h |
50 | CH2 end (µs) |
NUM_PULSES |
discharge.h |
8 | Pulses per train |
NUM_APROX_STEPS |
stepper.h |
1 | Fine approach steps |
NUM_STEPS_MID |
stepper.h |
50 | Retract steps |
NUM_QUICK_STEPS |
stepper.h |
35000 | Fast move steps |
TIME_BETWEEN_STEPS |
stepper.h |
300 | TIM2 ticks per STEP phase |
Stepper_Stop() from a button or fault event).